Guercon Automation
Zonne-Energie

 














 

Technische Componenten: De regulators

Het model HL-6

Multi-function:

·        Water lever Preset

·        Water temperature preset

·        Timer for water loading Auto water loading

·        Pipe temperature keeping Intelligent Heating

·        Intelligent water loading No water alarm

·        Manual control Timer heating

·        Electricity leakage protection low water pressure water loading

·        Auto control for boosting pump

Technical data:

·        Temperature detect range: 0-99 C

·        Precision: +/- 2 C

·        Water level: 5 level

·        Power source:220V AC Consumption < 5w

·        Electric heater belt and water pump power controllable < 500w

·        Electric heater back up power < 2000W

Het model S868C3E-1 controller

Functions:

·        Functional display

·        Up to 2 temperature sensor for tanks

·        Optionally: pump speed control, solar operating hours counter and

·        Thermostat function

·        Temperature difference circulation 2-15° C (default 10° C )

·        Housing in outstanding design and easy user friendly operation

·        PT1000 temperature sensor

Features:

·        Outline sizes of display: 120x120x18mm

·        Power consumption:<5W

·        Accuracy of temperature measuring: +/-2° C

·        Range of temperature measuring:
0-99° C

·        Controlled power of circulation pump: <600W

·        Power of electric heating</=2kw

·        S868C3E-1 controller is used for high pressure solar thermal systems, persuades by a clear operating concept and is equipped with the newly developed illuminated combined display with system monitoring.

·        Flashing display for sensors, pumps, and electric heater enable an immediate allocation of the temperatures, temperature difference and active actuators.

·        Adjustment and control of the solar system can be easily realized.